gracielly barros retweeted
Proud to have performed the first-in-USA case with the Paraclose (@AbbottNews) PVL occluder @HMHNewJersey. A purpose-built device after years of off-label options is a big step for our patients.
Case details below with @ryankaple, @PWengrofskyMD
#StructuralHeart #PVL #CardioTwitter
3D segmentation of the tricuspid valve โ Step by step with 3D Auto TV #philips. Static review โ Commissure points โ Dynamic review โ Analysis.
Mitral Regurgitation with Multiple Jets: An Integrated and
Hierarchical Approach
doi.org/10.36660/abcimg.2026โฆ
NEW ASE Recommendations for the Intraprocedural Imaging for M-TEER bit.ly/ASE_M-TEER @SLittleMD @ASE360 @JournalASEcho @ACCinTouch @SCAI @purviparwani @iamritu
Was honored to be discussant for landmark TRIC-I-HF Trial here @escardio See @NEJM simultaneous publication bit.ly/4cRywb3 #ESCCongress @j_hausleiter @PhilippLurz
gracielly barros retweeted
Choosing the right way to repair a leaking heart valve can be difficult because different procedures may restore function while placing different mechanical demands on the valve.
Investigating these tradeoffs, researchers developed an open-source finite element modeling framework to simulate transcatheter edge-to-edge repair (TEER), annuloplasty, and combined strategies in a patient-specific model of the mitral anatomy.
Simulations of prolapse and annular dilation showed that TEER could restore leaflet contact but increase leaflet stress, while annuloplasty altered valve mechanics differently and improved closure when dilation was present. In the dilation model, combining TEER with band annuloplasty produced the smallest regurgitant opening, largest leaflet contact area, and lower stresses than TEER alone.
By enabling repair strategies to be evaluated virtually before intervention, this framework could support more individualized procedural decisions and inform the development of future mitral valve therapies.
๐ฅ๐ฒ๐ฎ๐ฑ ๐บ๐ผ๐ฟ๐ฒ: link.springer.com/article/10โฆ
๐ฆ๐๐๐ฑ๐: Simulation of Transcatheter Therapies for Atrioventricular Valve Regurgitation in an Open-Source Finite Element Simulation Framework
๐๐๐๐ต๐ผ๐ฟ๐: Seda Aslan, Nicolas R. Mangine, @DW_Laurence, Patricia M. Sabin, @wensi_wu, Christian Herz, Justin S. Unger, @SteveMaas, @mjgillespie1, @JeffWeissUT, and Matthew A. Jolley
@ChildrensPhila
@UUtah
@UtahCOE
@UtahBME
@uusci
@JolleyLab
๐ฆ๐๐ฏ๐บ๐ถ๐ ๐๐ผ๐๐ฟ ๐บ๐ฎ๐ป๐๐๐ฐ๐ฟ๐ถ๐ฝ๐: link.springer.com/journal/10โฆ
Successful transcatheter closure of a mitral paravalvular leak, with marked reduction in regurgitation and resolution of systolic pulmonary vein flow reversal.
gracielly barros retweeted
๐ก๐๐๐๐ ๐๐ข๐ (๐๐ซ๐๐ง๐ฌ ๐๐ข๐ญ๐ซ๐๐ฅ ๐๐๐ฅ๐ฏ๐ ๐๐ฆ๐ฉ๐ฅ๐๐ง๐ญ๐๐ญ๐ข๐จ๐ง - ๐๐๐ฅ๐ฏ๐ ๐ข๐ง ๐๐ข๐ง๐ )
performed in our Hospital Cittร di Lecce - GVM
๐ 82 years old, 15 y ago mitral annuloplasty with semirigid ring 32 mm. Admitted for SOB and heart failure.
๐ Prep-OP 2D/3D TEE clearly shows failure of previous annuloplasty with severe MR due to a complex mechanism โก๏ธ P3 prolapse, A2-P2 restricted motion, large central coaptation defect.
๐งโโ๏ธ Heart Team discussion: fragility, several comorbidities, high surgical risk.
๐ฅ Pre-OP imaging: Cardiac CT and TEE
Percutaneous solutions:
โ M-TEER: unfavorable anatomy
โ
TMVI ViR
๐ Transeptal approach and proper 27.5 mm bioprosthesis implantation .
๐ Normal mean gradient, no MR, trivial PVL, no LVOT obstruction.
MICS (Minimally invasive and Catheter Solutions) pays off!
gracielly barros retweeted
My #echofirst Approach to PISA EROA in Mitral Regurgitation: A Critical Review doi.org/10.36660/abcimg.2024โฆ
Excited to share our latest work on T-TEER! We break down how to mirror M-TEER workflows for the TVโhighlighting key anatomic parallels, imaging strategies, procedural steps to simplify a complex intervention. A practical step-by-step guide
Link -> bit.ly/3Q0gURZ
gracielly barros retweeted
Mitral valve prolapse dynamics as you have imagined: AI reconstructed 4D CT Is this the future? ow.ly/TGuv50ZafF1
#AICardiology #EHJCaseReports @Phiso_de @TJ_Yeo @aayshacader @girishviswa @SukritiBanthiya @O_Azizy_MD @saramoscatelli7 @EHJCREiC #CardioX
Mitral repair is more than fixing prolapse.
Understanding the interplay between A2 height, C-Sept distance, and coaptation length is essential to predict and prevent SAM, while maximizing repair durability. #CardiacSurgery #TEE #MitralValveRepair #StructuralHeart
gracielly barros retweeted
๐ซ Did you know where the recommendation to place the pulsed wave Doppler sample volume 0.5โ1 cm from the aortic valve to measure LVOT VTI comes from?
The answer is more interesting than it seems. It doesnโt come from a single study or an experiment designed for that purpose. It comes from a historical chain spanning nearly 40 years:
๐ฌ 1982โ1984 โ The physical foundation
Pasipoularides and Murgo demonstrated using invasive catheters and mathematical models that in aortic stenosis there is a real zone of flow acceleration in the LVOT, just proximal to the valve, without any second anatomic obstruction. Pure hemodynamics โ no Doppler yet.
๐ Bird et al. Circulation 1982 โ doi.org/10.1161/01.CIR.66.4.โฆ
๐ Pasipoularides et al. Am J Physiol 1984 โ doi.org/10.1152/ajpheart.198โฆ
๐ 1984 โ The apical 5-chamber view
Lewis, Kuo and Quinones were the first to validate cardiac output measurement using pulsed wave Doppler from the cardiac apex. They described placing the sample volume โimmediately proximal to the aortic valve leafletsโ โ but without specifying any distance in centimeters.
๐ Lewis et al. Circulation 1984 โ doi.org/10.1161/01.CIR.70.3.โฆ
๐ 1985 โ The first numerical distance
Skjaerpe, Hegrenaes and Hatle (the Norwegian group) were the first to quantify this in Doppler: they empirically observed that flow acceleration began 0.5 to 1.5 cm proximal to the valve, and placed the sample volume just proximal to that zone. They directly cited Pasipoularides as supporting evidence. This was the first time a numerical distance appeared in the technique.
๐ Skjaerpe et al. Circulation 1985 โ doi.org/10.1161/01.CIR.72.4.โฆ
๐ 1986โ1988 โ Practical consolidation
Otto et al. used ~1.0 cm. Oh, Tajik and the Mayo Clinic group explicitly established the range of 0.5 to 1.0 cm in 100 patients, justifying it as necessary to avoid the subvalvular acceleration zone. This is the figure we all recognize today.
๐ Otto et al. JACC 1986 โ doi.org/10.1016/S0735-1097(8โฆ
๐ Zoghbi et al. Circulation 1986 โ doi.org/10.1161/01.CIR.73.3.โฆ
๐ Oh et al. JACC 1988 โ doi.org/10.1016/0735-1097(88โฆ
๐ 2002 โ It becomes โofficialโ
Quinones, Otto, Zoghbi and colleagues codified it in the ASE guidelines as โ~5 mm proximal to the aortic valveโโฆ but without citing any specific study to support it. It had already become expert consensus.
๐ Quiรฑones et al. JASE 2002 โ doi.org/10.1067/mje.2002.120โฆ
โ๏ธ 2017 โ The debate reopens
Baumgartner et al. (EACVI/ASE) maintained the 0.5โ1 cm recommendation. However, Hahn and Pibarot responded with a critical letter pointing out that the original articles from the 1980s measured at the aortic annulus, not 0.5โ1 cm below it, and that moving away from the annulus introduces errors due to the elliptical and irregular shape of the subannular LVOT.
๐ Baumgartner et al. Eur Heart J Cardiovasc Imaging 2017 โ doi.org/10.1093/ehjci/jew335
๐ Hahn & Pibarot. JASE 2017 โ doi.org/10.1016/j.echo.2017.โฆ
๐ก Bottom line:
The 0.5โ1 cm figure was never experimentally validated as the optimal distance. It emerged from empirical observations in the 1980s aimed at avoiding a flow acceleration zone that had been demonstrated with invasive catheters. It was adopted through accumulated clinical practice and later elevated to a formal recommendation by consensus. The debate over whether to measure at the annulus or 0.5โ1 cm below it remains open to this day.
One of those recommendations we all follow but few know where it actually came from ๐
Dr Benigno Valderrรกbano Salas
@MDBeni
@JaeKOh2 @ottoecho @WilliamZoghbi @ASE360 @EACVIPresident @NephroP @iamritu @PPibarot @hahn_rt @MAecocardio @SISIACOficial @SONECOM_AC @VazyurVasquez @Cardiotweets83 @HEARTof_echo @echobasics
Echo-derived surrogates of RVโPA coupling may mislead when interpreted in isolation.
TAPSE/PASP ~0.31, with reduced RV strain (-14.9%) and 3D RVEF (39%), illustrates early maladaptive remodeling and evolving uncoupling.
The number is intermediate. The ventricle is not.
2
1
145
gracielly barros retweeted
Position Statement on Multimodality Cardiac Imaging in Patients with Systemic Diseases โ 2026 doi.org/10.36660/abc.2026022โฆ
๐ฃ๏ธ Proud to share the new document of the Brazilian Society of Cardiology.
๐ This is an unprecedented document led by a CV Imaging society that we know.
Just published bit.ly/TR-Standard_WU Hoping to standardize identification of appropriate patients for TTVI! @ESCardioNews @ESC_Journals @escardio @ACCinTouch @juliendreyfus1 @FabienPraz @NAjmoneMarsan @denisamuraru
TCT LATAM VALVES.
Mature discussions, a true focus on anatomy and patient selection, and a level of integration between imaging and intervention that defines the future of our practice. We keep evolving.
1
74
Functional TR is usually not a leaflet disease itโs a disease of the annulus and the RV.
RV overload โ tricuspid annulus dilation (mainly anterior & posterior) โ loss of leaflet coaptation โ TR.
Ring annuloplasty restores annular geometry and re-establishes leaflet coaptation. Fix the annulus, restore the valve. scienceopen.com/hosted-documโฆ
gracielly barros retweeted
A table from newly published AHA/ACC Pulmonary embolism guidelines
jacc.org/doi/10.1016/j.jacc.โฆ
Any comments from echocardiography colleagues?
gracielly barros retweeted
#EHJIMP ๐ซ TR regression after M-TEER ๐ก
Tricuspid valve annulus perimeter was the strongest predictor of TR regression in this study including 61 patients who underwent pre+post 3D #echofirst. Annulus area and area change also predicted TRโฌ๏ธ.
Read more: doi.org/10.1093/ehjimp/qyaf0โฆ





















