Testups (@testups18) header
Testups (@testups18) profile picture
Boston, MA
Joined July 2017
Photo by Testups (@testups18)Photo by Testups (@testups18)Photo by Testups (@testups18)Photo by Testups (@testups18)Photo by Testups (@testups18)Photo by Testups (@testups18)Photo by Testups (@testups18)Photo by Testups (@testups18)Photo by Testups (@testups18)Photo by Testups (@testups18)
A car part, an aircraft box and a smart speaker can all end up in an EMC chamber. They follow different rulebooks: FCC Part 15, CISPR 25, RTCA DO-160, IEC 61000-4-3. Inside the Chamber 12/14 testups.com #EMC #EMCTesting
4
Happy Thanksgiving to everyone celebrating in the US. Today, a thank-you to the shielded EMC chamber: the quiet room that lets the devices on today's table work side by side. Inside the Chamber 11/14 testups.com #Thanksgiving #EMC
4
In most EMC tests, nobody is inside the chamber. The engineers sit next door in the control room, so they don't influence the measurement. Inside the Chamber 10/14 testups.com/emc-labs/ #EMC #TestLab
1
13
Every EMC chamber asks two opposite questions about a product. Is it too loud? (emissions) Is it too sensitive? (immunity) In one test the chamber listens. In the other, it shouts. Inside the Chamber 9/14 testups.com #EMC #EMCTesting
3
The biggest hole in a shielded chamber is the one everybody walks through. A shielded door must seal the shield completely every time it closes, dozens of times a day. Inside the Chamber 8/14 testups.com #EMC #ShieldedRoom
4
What happens to an anechoic chamber when its first lab no longer needs it? Often it gets a second life: absorbers inspected, seals renewed, shielding tested again. Inside the Chamber 7/14 testups.com #EMC #AnechoicChamber
4
Why is there no "standard size" EMC chamber? Because the key dimension is the measurement distance inside it: most often 3 m or 10 m. That one number shapes the whole room. Inside the Chamber 6/14 testups.com #EMC #AnechoicChamber
2
In a radiated emissions test, nothing stands still. The product turns to find its strongest direction, and the antenna moves up and down (in the lower frequency range) to find the strongest height. Inside the Chamber 5/14 testups.com/emc-labs/ #EMC #EMCTesting
8
Not every EMC test room is made of steel. RF shielded tents use shielding fabric, go up inside an existing hall, and pack away for the next site. Every opening is still a possible leak. Inside the Chamber 4/14 testups.com #EMC #ShieldedTent
1
9
A shielded chamber has to breathe, get power and pass cables. Each is a hole in a box built to have none. Honeycomb vents, EMI filters and an RF I/O panel let air, power and signals through, but not radio waves. Inside the Chamber 3/14 testups.com #EMC #EMIFilter
1
12
Those blue pyramids in an EMC chamber are not decoration, and not soundproofing. They are RF absorbers. They soak up radio waves so reflections from the walls don't distort the measurement. Inside the Chamber 2/14 zurl.co/4oEk4 #EMC #RFAbsorber
17
An EMC anechoic chamber looks like part of the building. It isn't. It can be taken apart, shipped and rebuilt. "Can it move?" is the easy question. "Will it measure the same after the move?" is the real one. Inside the Chamber 1/14 zurl.co/2bxxe #EMC #AnechoicChamber
14
See a TESTUPS turnkey EMC lab come together — a 75-sec animated 3D walkthrough: RF door, 9 × 6 × 6 m semi-anechoic chamber designed for CISPR 16 site validation, turntable + mast, antennas covering 10 Hz – 40 GHz. zurl.co/qDKYG #EMC #EMCTesting #AnechoicChamber
2
1
24
Why is an EMC test chamber lined with blue pyramids? They're RF absorbers: they soak up radio waves so wall and ceiling reflections don't distort measurements. Animated 3D visualization, source: TESTUPS. Full 90-second walkthrough: testups.com/emc-labs/ #EMC #AnechoicChamber
1
2
44
Step inside a TESTUPS turnkey EMC test lab — a 90-sec animated 3D walkthrough: 9 × 6 × 6 m anechoic chamber, CISPR 16, 10 Hz – 40 GHz, emissions + immunity test systems, amplifier & control rooms. zurl.co/FF1sz #EMC #EMCTesting #AnechoicChamber
1
1
69
Definition of ElectroMagnetic Compatibility: #EMC #Electronics #EMI #EMS
1
43
Do you want to perform electromagnetic compatibility tests of long vehicles like buses? We are offering EMC Anechoic Chambers which are used for long vehicle testing? Compliant with CISPR 12 (emissions) and ISO 11451-2 (immunity) standards. #EMC #Automotive #LongVehicle #Ebus
1
75